var Device = require('./Device');
BrickletCO2.DEVICE_IDENTIFIER = 262;
BrickletCO2.DEVICE_DISPLAY_NAME = 'CO2 Bricklet';
BrickletCO2.CALLBACK_CO2_CONCENTRATION = 8;
BrickletCO2.CALLBACK_CO2_CONCENTRATION_REACHED = 9;
BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION = 1;
BrickletCO2.FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_PERIOD = 2;
BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_PERIOD = 3;
BrickletCO2.FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_THRESHOLD = 4;
BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_THRESHOLD = 5;
BrickletCO2.FUNCTION_SET_DEBOUNCE_PERIOD = 6;
BrickletCO2.FUNCTION_GET_DEBOUNCE_PERIOD = 7;
BrickletCO2.FUNCTION_GET_IDENTITY = 255;
BrickletCO2.THRESHOLD_OPTION_OFF = 'x';
BrickletCO2.THRESHOLD_OPTION_OUTSIDE = 'o';
BrickletCO2.THRESHOLD_OPTION_INSIDE = 'i';
BrickletCO2.THRESHOLD_OPTION_SMALLER = '<';
BrickletCO2.THRESHOLD_OPTION_GREATER = '>';
function BrickletCO2(uid, ipcon) {
//Measures CO2 concentration in ppm
/*
Creates an object with the unique device ID *uid* and adds it to
the IP Connection *ipcon*.
*/
Device.call(this, this, uid, ipcon);
BrickletCO2.prototype = Object.create(Device);
this.responseExpected = {};
this.callbackFormats = {};
this.APIVersion = [2, 0, 0];
this.responseExpected[BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION] = Device.RESPONSE_EXPECTED_ALWAYS_TRUE;
this.responseExpected[BrickletCO2.FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_PERIOD] = Device.RESPONSE_EXPECTED_TRUE;
this.responseExpected[BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_PERIOD] = Device.RESPONSE_EXPECTED_ALWAYS_TRUE;
this.responseExpected[BrickletCO2.FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_THRESHOLD] = Device.RESPONSE_EXPECTED_TRUE;
this.responseExpected[BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_THRESHOLD] = Device.RESPONSE_EXPECTED_ALWAYS_TRUE;
this.responseExpected[BrickletCO2.FUNCTION_SET_DEBOUNCE_PERIOD] = Device.RESPONSE_EXPECTED_TRUE;
this.responseExpected[BrickletCO2.FUNCTION_GET_DEBOUNCE_PERIOD] = Device.RESPONSE_EXPECTED_ALWAYS_TRUE;
this.responseExpected[BrickletCO2.CALLBACK_CO2_CONCENTRATION] = Device.RESPONSE_EXPECTED_ALWAYS_FALSE;
this.responseExpected[BrickletCO2.CALLBACK_CO2_CONCENTRATION_REACHED] = Device.RESPONSE_EXPECTED_ALWAYS_FALSE;
this.responseExpected[BrickletCO2.FUNCTION_GET_IDENTITY] = Device.RESPONSE_EXPECTED_ALWAYS_TRUE;
this.callbackFormats[BrickletCO2.CALLBACK_CO2_CONCENTRATION] = 'H';
this.callbackFormats[BrickletCO2.CALLBACK_CO2_CONCENTRATION_REACHED] = 'H';
this.getCO2Concentration = function(returnCallback, errorCallback) {
/*
Returns the measured CO2 concentration. The value is in
`ppm (parts per million) <https://en.wikipedia.org/wiki/Parts-per_notation>`__
and between 0 to 10000.
If you want to get the CO2 concentration periodically, it is recommended to use the
callback :func:`CO2Concentration` and set the period with
:func:`SetCO2ConcentrationCallbackPeriod`.
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION, [], '', 'H', returnCallback, errorCallback);
};
this.setCO2ConcentrationCallbackPeriod = function(period, returnCallback, errorCallback) {
/*
Sets the period in ms with which the :func:`CO2Concentration` callback is triggered
periodically. A value of 0 turns the callback off.
:func:`CO2Concentration` is only triggered if the CO2 concentration has changed since the
last triggering.
The default value is 0.
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_PERIOD, [period], 'I', '', returnCallback, errorCallback);
};
this.getCO2ConcentrationCallbackPeriod = function(returnCallback, errorCallback) {
/*
Returns the period as set by :func:`SetCO2ConcentrationCallbackPeriod`.
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_PERIOD, [], '', 'I', returnCallback, errorCallback);
};
this.setCO2ConcentrationCallbackThreshold = function(option, min, max, returnCallback, errorCallback) {
/*
Sets the thresholds for the :func:`CO2ConcentrationReached` callback.
The following options are possible:
.. csv-table::
:header: "Option", "Description"
:widths: 10, 100
"'x'", "Callback is turned off"
"'o'", "Callback is triggered when the CO2 concentration is *outside* the min and max values"
"'i'", "Callback is triggered when the CO2 concentration is *inside* the min and max values"
"'<'", "Callback is triggered when the CO2 concentration is smaller than the min value (max is ignored)"
"'>'", "Callback is triggered when the CO2 concentration is greater than the min value (max is ignored)"
The default value is ('x', 0, 0).
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_THRESHOLD, [option, min, max], 'c H H', '', returnCallback, errorCallback);
};
this.getCO2ConcentrationCallbackThreshold = function(returnCallback, errorCallback) {
/*
Returns the threshold as set by :func:`SetCO2ConcentrationCallbackThreshold`.
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_THRESHOLD, [], '', 'c H H', returnCallback, errorCallback);
};
this.setDebouncePeriod = function(debounce, returnCallback, errorCallback) {
/*
Sets the period in ms with which the threshold callbacks
* :func:`CO2ConcentrationReached`,
are triggered, if the thresholds
* :func:`SetCO2ConcentrationCallbackThreshold`,
keep being reached.
The default value is 100.
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_SET_DEBOUNCE_PERIOD, [debounce], 'I', '', returnCallback, errorCallback);
};
this.getDebouncePeriod = function(returnCallback, errorCallback) {
/*
Returns the debounce period as set by :func:`SetDebouncePeriod`.
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_GET_DEBOUNCE_PERIOD, [], '', 'I', returnCallback, errorCallback);
};
this.getIdentity = function(returnCallback, errorCallback) {
/*
Returns the UID, the UID where the Bricklet is connected to,
the position, the hardware and firmware version as well as the
device identifier.
The position can be 'a', 'b', 'c' or 'd'.
The device identifier numbers can be found :ref:`here <device_identifier>`.
|device_identifier_constant|
*/
this.ipcon.sendRequest(this, BrickletCO2.FUNCTION_GET_IDENTITY, [], '', 's8 s8 c B3 B3 H', returnCallback, errorCallback);
};
}